owner's manual
MODEL NOS:
4505622; 6005622
FOR USE WITH
NATURAL GAS ONLY
MODEL NOS.
4505621 ; 6005621
FOR USE WITH
LIQUEFIED
PETROLEUM (L.P.)
GAS ONLY
INSTALLATION & OPERATING INSTRUCTION MANUAL
GRAVITY VENTED FLOOR FURNACE
60056 MODEL SERIES SHOWN
READ THIS OWNER'S
MANUAL CAREFULLY
BEFORE YOU INSTALL
YOUR NEW WILLIAMS
FLOOR FURNACE
WARNING: Improper installation, adjust-
ment, alteration, service or maintenance
can cause injury or property damage.
Refer to this manual. For assistance or
additional information consult a qualified
installer, service agency or the gas
supplier.
WARNING: Do not install any of these fur-
naces (Natural or L.P. Gas) in mobile
homes, traders, or recreational vehicles.
l WARNING: If the information in this
manual is not followed exactly, a fire or ex-
plosion may result causing property
damage, personal injury or loss of life.
-- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity
of this or any other appliance.
-- WHAT TO DO IF YOU SMELL GAS
Open all windows.
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Extinguish any open flame.
Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instruction.
if you cannot reach your gas supplier,
call the fire department.
-- Installation and service must be per-
formed by a qualified installer, service
agency or the gas supplier.
WILLIAMS Furnace Co., 225 Acacia St., Colton, CA 92324
PRINTED IN USA 4/99 P322436
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - GRAVITY VENTED FLOOR FURNACE

owner's manualMODEL NOS:4505622; 6005622FOR USE WITHNATURAL GAS ONLYMODEL NOS.4505621 ; 6005621FOR USE WITHLIQUEFIEDPETROLEUM (L.P.)GAS ONLYINSTA

Page 2 - Your Warranty

Installation (cont.)20. Turn on the gas and check all gas fittingsfor leaks with asoapy water solution or a liquid leak detection solution.DO NOT USE

Page 3

Installation (cont.)22. Check the vent or chimney performance by holding amatch near the edge of the drafthood as shown in Figure12. If the flame is n

Page 4 - Safety Rules

FOR YOUR SAFETY READ BEFORE LIGHTINGI WARNING: If you do not follow these instructions exactly, a fire or explosion Imay result causing property damag

Page 5 - SECTION OF THIS MANUAL

Operating The FurnaceAlways follow the instructions located beneath the furnacegrille when lighting the pilot. To set the thermostat, turn thetemperat

Page 6 - Locating Floor Furnace

Troubleshooting Floor FurnaceSYMPTOM1. Flame too large.2. Noisy flame.3. Yellow tip flame.4, Floating flame.5. Delayed ignition.6. Failure to ignite.7

Page 7 - WRONG RIGHT

Troubleshooting Floor Furnace cont.SYMPTOM10. Not enough heat.11. Too much heat.POSSIBLE CAUSEA. Thermostat set too low.B. Appliance close to thermost

Page 8 - LEAD V_RES

REPLACEMENT PARTS FOR MODELS4505621 4505622 6005621 6005622KEY DESCRIPTION 4505621 4505622 6005621 6005622NO.1 P322426 P3224292 480041 4800423 480056-

Page 9 - Installation

WILLIAMS GAS FIRED FLOOR FURNACEREPLACEMENT PARTS FOR450 & 600 MODEL SERIES(FLOOR FURNACE) FOR PARTS LISTINGSEE PAGE 16USE ONLY MANUFACTURERSAUTHO

Page 12 - TO TURN OFF GAS TO APPLIANCE!

Your WarrantyThe Manufacturer, Williams Furnace Co.. warrants this wall furnace or heater to the original purchaser under the following conditions:LIM

Page 13 - Operating The Furnace

ownersmanualMODEL NOS.FOR NAT. GAS ONLY4505622; 6005622MODEL NOS.FOR L.R GAS ONLY4505621;6005621Service HintsIf your furnace fails to work right, you

Page 14 - Troubleshooting Floor Furnace

BUILDING CODES AND SAFETY STANDARDSTHE DESIGN OF THIS FURNACE IS NOT CERTIFIED FOR USE IN MOBILE HOMES, TRAVELTRAILERS OR CAMPERS. THIS FURNACE MUST B

Page 15

Safety RulesWARNING 4. LOCATE the furnace out of traffic patterns as much asREAD THESE RULES AND THE INSTRUCTIONSCAREFULLY. FAILURE TO FOLLOW THESERUL

Page 16 - REPLACEMENT PARTS FOR MODELS

KEEP THESE INSTRUCTIONSAll furnaces require a supply of oxygen for combustion. Toassure thisfurnace receives the necessary oxygen, two freeair opening

Page 17 - REPLACEMENT PARTS FOR

Locating Floor FurnaceConsider the following points before attempting to install thefurnace:1. To achieve the best results from this furnace, it must

Page 18

Venting And Chimney RequirementsProper venting of this furnace is required to prevent therelease of hazardous gases into the dwelling. The furnacemust

Page 19

Gas Supply And Piping RequirementsGas pipe must be installed by a qualified installer. The pipesystem must comply with the latest edition of the Ameri

Page 20 - 4505621;6005621

Installation1. Lay an outline of the furnace in the selected location,and draw diagonally from each corner of the outline asshown in Figure 6.2. Drive