Operating The Furnace
Always follow the instructions located beneath the furnace
grille when lighting the pilot. To set the thermostat, turn the
temperature selector to the highest setting until the heated
area reaches the desired temperature, then move the selector
slowly toward a lower setting until the furnace control cycles
off the burner. At this setting, the furnace should cycle on
and off as required to maintain the desired temperature.
WARNING
THE SURFACE OF THE FURNACE IS HOT DURING
OPERATION. KEEP CHILDREN, CLOTHING,
FURNITURE AND FLAMMABLE MATERIAL AWAY
FROM THE FURNACE.
This furnace is equipped with a control that limits the tem-
perature of the furnace grille by cycling the main burner.
This control may be overridden to allow more heat output
from the furnace during extreme weather when the furnace
will not provide sufficient heat otherwise. The overide
mechanism is located beneath the grilleonthe control end.
To override the temperature limit control, pull up on the
chain attached to the grille until the flap bearing the
"Register Hot--" warning is in the horizontal position. Insert
chain through slot to the side of the flap to hold flap in the
horizontal position (see Figure 13). To reactivate the tam-
perature limit control, remove chain from slot and the flap
will hang down. Do not override the temperature limit con-
trol if the furnace is in an area occupied by children or
elderly persons who could fall on the furnace and be
burned.
FIGURE 13
How To Care For Your Furnace
Service, repair or maintenance of the furnace, vent or gas
system should only be attempted by a qualified service
technician.
The burner and control of the furnace should be cleaned and
checked at least once each year by a qualified service
technician. If there is any indication that the furnace is
operating improperly, turn it off and have it checked
immediately.
Lint and dust may be vacuumed from the interior of the
furnace, when it is cool, by removing the floor grille. The
control and main burner can be blown free of dust and lint
with a vacuum cleaner.
WARNING
I DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE LIQUIDS OR VAPORS NEAR THE
FURNACE.
If the combustion chamber must be removed for servicing -
1. Turn the gas off at the main gas line shut-off valve.
2. Remove the floor grille and lift out the inner casing.
3. Lift the control end of the combustion chamber slightly,
slide the chamber toward the end of the cabinet about
one inch and then lift it out of the cabinet.
WARNING
DANGER OF BODILY INJURY OR DEATH
DO NOT OPERATE THE FURNACE WITH A
BROKEN OR MISSING PILOT OBSERVATION
DOOR.
If the control and main burner assembly must be removed
for servicing -
1. Turn the gas off at the main shut-off valve.
2. Disconnect the union in the gas supply line_
3. Remove the thermostat control wires from the gas control.
4. Remove the nuts that attach the gas control to the furnace
outer casing.
5. Remove the control assembly.
6. Remove the screw that attache s the control end of the
burner to the outer casing.
7. Slide the bumer forward until the control end of the bumer
can be dror)peddow n and pul! the burne[ OUtof the outer
casing.
This should be done by a qualified service technician.
If the furnace will oot be used for a long period of time, turn
the control knob to the "OFF" positionand turn off the shut-
off valve in the gas line serving the furnace.